Uploaded image for project: 'MedMij Standaarden'
  1. MedMij Standaarden
  2. MM-949

Profile OxygenSaturation calls out CodeSystem instead of ValueSet

    Details

    • Type: Wijzigingsverzoek
    • Status: Gesloten
    • Priority: 3
    • Resolution: Resolved
    • Fix Version/s: 2019.01 - April 2020
    • Blokkerend:
      Ja
    • Informatiestandaard:
      Zelfmetingen
    • Informatiestandaard onderdeel:
      FHIR
    • Impact:
      Something unimplementable will become implementable
    • FHIR Category:
      Profiles
    • Voorgestelde oplossing:
      Update valueSetReference for V2 ValueSet 0136 to http://hl7.org/fhir/ValueSet/v2-0136.
    • Release notes:
      Hide

      The ExtraOxygenAdministration concept in the zib-OxygenSaturation profile was illegally bound on a CodeSystem. This binding has been changed to the corresponding ValueSet.

      Show
      The ExtraOxygenAdministration concept in the zib-OxygenSaturation profile was illegally bound on a CodeSystem. This binding has been changed to the corresponding ValueSet.

      Description

      IG Publisher:

      StructureDefinition/zib-OxygenSaturation: StructureDefinition.snapshot.element[94].binding.valueSet.ofType(Reference) error Unable to find matching profile for http://hl7.org/fhir/v2/0136 (by type) among choices: ; [CanonicalTypehttp://hl7.org/fhir/StructureDefinition/ValueSet]
      StructureDefinition/zib-OxygenSaturation: StructureDefinition.snapshot.element[94].binding.valueSet.ofType(Reference) error Invalid Resource target type. Found CodeSystem, but expected one of ([ValueSet])
      StructureDefinition/zib-OxygenSaturation: StructureDefinition.differential.element[12].binding.valueSet.ofType(Reference) error Unable to find matching profile for http://hl7.org/fhir/v2/0136 (by type) among choices: ; [CanonicalTypehttp://hl7.org/fhir/StructureDefinition/ValueSet]
      StructureDefinition/zib-OxygenSaturation: StructureDefinition.differential.element[12].binding.valueSet.ofType(Reference) error Invalid Resource target type. Found CodeSystem, but expected one of ([ValueSet])

      This profile calls out to the V2 CodeSystem 0136 instead of the V2 ValueSet 0136

      We should change:

      <reference value="http://hl7.org/fhir/v2/0136" />

      into

      <reference value="http://hl7.org/fhir/ValueSet/v2-0136" />

        Attachments

          Activity

            People

            Assignee:
            e.derijcke@furore.com Eduard de Rijcke
            Reporter:
            henket Alexander Henket
            Watchers:
            0 Start watching this issue

              Dates

              Created:
              Updated:
              Resolved:

                Estimations By Role

                No roles have been estimated yet.