CLONE - Search parameters op codesysteem moeten eindigen op |
Description
Verduidelijking van Impact
Proposed solution (NL)
Toevoegen van een "bekend issue" met als tekst "Note that the query for Lab results should have a trailing pipe symbol in the value of the code parameter. We intend to fix this in the next major release of this information standard. Please see MM-529(link) for details."
Ten behoeve van de backlog geldt dan het volgende:
Pipe toevoegen in de query url in de technische informatiestandaard
Pipe toevoegen in de query url in het FHIR TestScript
Proposed solution (EN)
Release notes (NL)
The implementation guide for GP data misses a pipe symbol in the URL for querying Laboratoriumbepalingen, which is not conform the FHIR API. However, many systems have already been qualified using this errornous method. Therefore this issue will not be fixed until the next major release, and currently a warning is added to the implementation guide.
Release notes (EN)
is related to
Activity

Niek van Galen October 30, 2019 at 3:49 PM
Wijziging gepubliceerd in de Oktober-release versie 2019.01.
Details
Details
Assignee

Reporter

In Huisartsgegevens technisch ontwerp staat een query op NHG Tabel 45. Hier ontbreekt een verplicht | symbool na het codesysteem. Hierdoor zal het codesysteem gelezen worden als code conform de search specificatie van FHIR.
Verzoek om deze | toe te voegen. Let op dat het denkbaar is dat dit voor meer technische ontwerpen geldt.