Uploaded image for project: 'MedMij Standaarden'
  1. MedMij Standaarden
  2. MM-601

CLONE - Search parameters op codesysteem moeten eindigen op |

    Details

    • Type: Wijzigingsverzoek
    • Status: Gesloten
    • Priority: 3
    • Resolution: Resolved
    • Fix Version/s: 2019.01 - Oktober 2019
    • Blokkerend:
      Ja
    • Informatiestandaard:
      Huisartsgegevens
    • Informatiestandaard onderdeel:
      Technisch
    • Impact:
      For already qualified systems, there will be no impact. New systems that are based a reference FHIR framework will have to work around the incorrect query.
    • Beproeving:
      POC
    • Voorgestelde oplossing:
      Hide
      * Toevoegen van een "bekend issue" met als tekst "Note that the query for Lab results should have a trailing pipe symbol in the value of the code parameter. We intend to fix this in the next major release of this information standard. Please see MM-529(link) for details."

      Ten behoeve van de backlog geldt dan het volgende:
      * Pipe toevoegen in de query url in de technische informatiestandaard
      * Pipe toevoegen in de query url in het FHIR TestScript
      Show
      * Toevoegen van een "bekend issue" met als tekst "Note that the query for Lab results should have a trailing pipe symbol in the value of the code parameter. We intend to fix this in the next major release of this information standard. Please see MM-529 (link) for details." Ten behoeve van de backlog geldt dan het volgende: * Pipe toevoegen in de query url in de technische informatiestandaard * Pipe toevoegen in de query url in het FHIR TestScript
    • Abstract:
      Hide

      Zie voorgestelde oplossing.

      Show
      Zie voorgestelde oplossing.
    • Release notes:
      Hide

      The implementation guide for GP data misses a pipe symbol in the URL for querying Laboratoriumbepalingen, which is not conform the FHIR API. However, many systems have already been qualified using this errornous method. Therefore this issue will not be fixed until the next major release, and currently a warning is added to the implementation guide.

      Show
      The implementation guide for GP data misses a pipe symbol in the URL for querying Laboratoriumbepalingen, which is not conform the FHIR API. However, many systems have already been qualified using this errornous method. Therefore this issue will not be fixed until the next major release, and currently a warning is added to the implementation guide.

      Description

      In Huisartsgegevens technisch ontwerp staat een query op NHG Tabel 45. Hier ontbreekt een verplicht | symbool na het codesysteem. Hierdoor zal het codesysteem gelezen worden als code conform de search specificatie van FHIR.

      Verzoek om deze | toe te voegen. Let op dat het denkbaar is dat dit voor meer technische ontwerpen geldt.