Uploaded image for project: 'Medicatieproces'
  1. Medicatieproces
  2. MP-347

FHIR timing in CDA substanceAdministration.effectiveTime

    Details

    • Type: Wijzigingsverzoek
    • Status: In publicatie
    • Priority: 2
    • Resolution: Resolved
    • Fix Version/s: MP9 2.0 bèta
    • Component/s: Templates
    • Release notes:
      Hide

      Introductie van het FHIR timing datatype in CDA substanceAdministration.effectiveTime voor toedieningsschema's. Voorheen was dit de HL7v3 GTS (General Timing Specification). De inhoudelijke wijziging in de xml schema's (xsd's) is op informatiestandaarden.nictiz.nl gedocumenteerd.

      Show
      Introductie van het  FHIR timing datatype  in CDA substanceAdministration.effectiveTime voor toedieningsschema's. Voorheen was dit de HL7v3 GTS (General Timing Specification). De inhoudelijke wijziging in de xml schema's (xsd's) is op informatiestandaarden.nictiz.nl gedocumenteerd.
    • Gepland voor:
      2.0.0
    • Zwaartecategorie:
      D - 'Majeur'
    • Releaseplanning:
      Eerstvolgende release

      Description

      After consulting with about ten vendors the question has risen to investigate whether we can use the FHIR timing datatype in CDA substanceAdministration.effectiveTime for the administration schedules.

      The HL7v3 GTS (General Timing Specification), which is based on set theory, does not translate easily into dosing schedules that human healthcare professionals use. It has proven to be very complex and error prone in MP version 6.12. We have attempted to make GTS unambiguous and 'one format for one administration schedule use case' in MP 9. However, even this attempt results in complex XML whilst the FHIR timing datatype is concrete and simple for the same use cases.

      We have consulted with developers from a variety of different vendors (hospital, personal health, general practitioner, pharmacy, thrombosis, infrastructure) and almost all expressed a preference for using FHIR timing over HL7v3 GTS. One person indicated to still need a bit of a think about it. No one had a preference for HL7v3 GTS.